Skip to main content
DigiCalcs

learn.howToCalculate

learn.whatIsHeading

The Wire Gauge Converter translates between four electrical wire sizing systems: AWG (American Wire Gauge, used in US/Canada/Mexico), SWG (Standard Wire Gauge, traditional British), mm diameter (continental European, scientific), and mm² cross-section (modern international standard, used in electrical codes globally). The calculator also displays maximum ampacity (current capacity in amps) and categorizes wire by typical use case (signal, low voltage, residential, heavy duty, industrial).

الصيغة

Diameter (mm) = 0.127 × 92^((36-AWG)/39); Cross-section (mm²) = π × (D/2)²; Ampacity rises non-linearly with cross-section
D
Diameter (mm) — Wire diameter, measured across
A
Cross-section Area (mm²) — Conducting area; primary ampacity factor

دليل خطوة بخطوة

  1. 1Enter wire value in any of the 4 systems
  2. 2Calculator finds closest match in standard wire reference table
  3. 3Outputs equivalent AWG, SWG, mm diameter, mm² cross-section, and max amperage
  4. 4AWG is logarithmic: each increment of 6 doubles the cross-section
  5. 5Color codes ampacity category for safety reference

أمثلة محلولة

الإدخال
AWG 14 (standard residential wiring)
النتيجة
SWG 15, 1.628mm dia, 2.08mm², 20A max — residential 120V circuits
الإدخال
2.5mm² (European residential)
النتيجة
AWG 14, SWG 15, equivalent to US residential standard
الإدخال
AWG 0 (large gauge for vehicle charging)
النتيجة
SWG 1, 8.252mm dia, 53.5mm², 150A — high-current applications

أخطاء شائعة يجب تجنبها

  • Confusing AWG (smaller number = larger wire) with metric (larger number = larger wire)
  • Using chassis ampacity for power transmission — power transmission ampacity is lower
  • Ignoring length-based voltage drop — longer wires need larger gauges
  • Mixing solid vs stranded ampacity ratings without checking codes

أسئلة شائعة

Why smaller AWG = larger wire?

AWG comes from the number of die-passes used to draw wire to size — more passes means thinner wire. AWG 36 needed 36 draws (very thin); AWG 0 was undrawn (thick). The system is logarithmic with base 92^(1/39), giving each 3-step decrement ~doubled cross-section.

Is AWG 14 or 12 better for 20A circuits?

AWG 12 is safer at 20A. US code requires AWG 14 for 15A circuits, AWG 12 for 20A circuits. Use the larger wire if uncertain — bigger gauge handles higher current with less voltage drop and heat.

هل أنت مستعد للحساب؟ جرب الآلة الحاسبة Wire Gauge Converter المجانية

جربه بنفسك →

الإعدادات